Fire Hatches

Fire hatches are tested and classified according to the requirements for hinged fire doors. Features are indicated according to the classification standard SFS-EN 13501-2:

  • Capability to prevent fire and flame spread are tested acc. to fire test standard SFS-EN 1634-1
  • Mechanical strength is tested acc. to SFS-EN 14600

EI260: construction opening max. 1150 mm wide and 2400 mm high.

Equipment

  • door leafs are made of zinc-coated steel plates
  • screw-fastening frame with cover lists, made of zinc-coated steel plates
  • lift hinges of steel
  • fitting for Abloy 4190T lock
  • reinforcements for pull and closer
  • cover caps for fastening holes
  • threshold same profile as the other parts of the frame
  • instructions for installation, handling, maintenance and

Accessories

  • kick plates
  • different door closer types
  • fitting and tubing for electric lock, door magnet, wires and lead cover, locations and models acc. to type approvals
  • alternative surface handling and powder painting, standard shades*)

 

 

*) Standard shades RAL

7001
Silver grey
7024
Graphite grey
7040
Window grey
7042
Traffic grey A
9002
Grey white
9010
Pure white
9016
Traffic white

– other colours according to tender.

Facebooktwitterlinkedinmail

Products

  • Marine division
  • Construction division
    • Hinged Fire Doors
    • Sliding Fire Doors
    • Fire Hatches
    • Pressure-proof fire doors
    • Burglary resistant fire doors
    • Acoustic Fire Doors
    • Glazed Fire Doors
    • Bullet-Proof Doors
    • Drawings and downloads
    • Certificates and Approvals for Construction Industry
  • Industrial specialities

·Toteutus ja ylläpito MMD Networks Oy·