Fire Hatches
Fire hatches are tested and classified according to the requirements for hinged fire doors. Features are indicated according to the classification standard SFS-EN 13501-2:
- Capability to prevent fire and flame spread are tested acc. to fire test standard SFS-EN 1634-1
- Mechanical strength is tested acc. to SFS-EN 14600
EI260: construction opening max. 1150 mm wide and 2400 mm high.
Equipment
- door leafs are made of zinc-coated steel plates
- screw-fastening frame with cover lists, made of zinc-coated steel plates
- lift hinges of steel
- fitting for Abloy 4190T lock
- reinforcements for pull and closer
- cover caps for fastening holes
- threshold same profile as the other parts of the frame
- instructions for installation, handling, maintenance and
Accessories
- kick plates
- different door closer types
- fitting and tubing for electric lock, door magnet, wires and lead cover, locations and models acc. to type approvals
- alternative surface handling and powder painting, standard shades*)
*) Standard shades RAL
7001 Silver grey |
7024 Graphite grey |
7040 Window grey |
7042 Traffic grey A |
9002 Grey white |
9010 Pure white |
9016 Traffic white |
– other colours according to tender.